Our Heavy Duty Diesel Generators Powered by Perkins deliver reliable performance in demanding environments. Available in both 50Hz and 60Hz configurations, they provide standby and prime power solutions ranging from 10 kVA to 2500 kVA.
Download
Our Heavy Duty Diesel Generators Powered by Perkins deliver reliable performance in demanding environments. Available in both 50Hz and 60Hz configurations, they provide standby and prime power solutions ranging from 10 kVA to 2500 kVA.
· Reliability & Durability:
Built with Perkins engines, our heavy duty diesel generators are designed for long-lasting, reliable power, even in the harshest environments.
· Fuel Efficiency:
Perkins-powered engines are known for their exceptional fuel efficiency, providing cost-effective and sustainable power solutions for various heavy-duty applications.
· Environmental Certification:
Our heavy duty diesel generators include Stage V Gensets, meeting the latest environmental standards for reduced emissions, ensuring eco-friendly operations.
Exceptional fuel efficiency for long running hours.
Stage V / Tier 4 compliant for reduced emissions and sustainable operations.
Global frequency compatibility with 50Hz and 60Hz options.
Rugged structure for heavy-duty industrial environments.
· Construction:
Reliable power for heavy machinery and large-scale equipment in tough on-site conditions.
· Mining:
Continuous, high-capacity power solutions for mining operations in remote or off-grid locations.
· Oil & Gas:
Robust energy support in challenging, high-demand environments, ensuring uninterrupted operations.
· Manufacturing:
Provide dependable power for large production facilities with heavy machinery and equipment.
· Emergency Backup:
Ensure critical infrastructure like hospitals and data centers have uninterrupted power during emergencies.
Looking for a reliable power solution? Explore our complete range of heavy duty diesel generators powered by Perkinsfrom 10 kVA to 2500 kVA. Contact us now to get a quote, download the product catalog, or speak with our technical expert for customized solutions.
PRODUCT LIST
| 50hz | ||||||
| Genset Model | Standby Power | Prime Power | Engine | |||
| kVA | kW | kVA | kW | Brand | Model | |
| VP10-5 | 10 | 8 | 9 | 7 | Perkins | 403D-11G |
| VP15-5 | 15 | 12 | 13 | 10 | Perkins | 403D-15G1 |
| VP16.5-5 | 16.5 | 13 | 15 | 12 | Perkins | 403A-15G2 |
| VP22-5 | 22 | 18 | 20 | 16 | Perkins | 404A-22G1 |
| VP33-5 | 33 | 26 | 30 | 24 | Perkins | 1103A-33G |
| VP50-5 | 50 | 40 | 45 | 36 | Perkins | 1103A-33TG1 |
| VP66-5 | 66 | 53 | 60 | 48 | Perkins | 1103A-33TG2 |
| VP72-5 | 72 | 58 | 65 | 52 | Perkins | 1104A-44TG1 |
| VP88-5 | 88 | 70 | 80 | 64 | Perkins | 1104A-44TG2 |
| VP110-5 | 110 | 88 | 100 | 80 | Perkins | 1104C-44TAG2 |
| VP150-5 | 150 | 120 | 135 | 108 | Perkins | 1106A-70TG1 |
| VP165-5 | 165 | 132 | 150 | 120 | Perkins | 1106A-70TAG2 |
| VP200-5 | 200 | 160 | 180 | 144 | Perkins | 1106A-70TAG3 |
| VP220-5 | 220 | 176 | 200 | 160 | Perkins | 1106A-70TAG4 |
| VP250-5 | 250 | 200 | 225 | 180 | Perkins | 1206A-E70TTAG2 |
| VP275-5 | 275 | 220 | 250 | 200 | Perkins | 1506A-E88TAG3 |
| VP275-5 | 275 | 220 | 250 | 200 | Perkins | 1206A-E70TTAG3 |
| VP330-5 | 330 | 264 | 300 | 240 | Perkins | 1506A-E88TAG5 |
| VP400-5 | 400 | 320 | 350 | 280 | Perkins | 2206C-E13TAG2 |
| VP450-5 | 450 | 360 | 400 | 320 | Perkins | 2206C-E13TAG3 |
| VP500-5 | 500 | 400 | 450 | 360 | Perkins | 2506C-E15TAG1 |
| VP550-5 | 550 | 440 | 500 | 400 | Perkins | 2506C-E15TAG2 |
| VP660-5 | 660 | 528 | 600 | 480 | Perkins | 2806C-E18TAG1A |
| VP700-5 | 700 | 560 | 650 | 520 | Perkins | 2806A-E18TAG2 |
| VP770-5 | 770 | 616 | 700 | 560 | Perkins | 2806A-E18TTAG4 |
| VP825-5 | 825 | 660 | 750 | 600 | Perkins | 4006-23TAG2A |
| VP880-5 | 880 | 704 | 800 | 640 | Perkins | 4006-23TAG3A |
| VP1000-5 | 1000 | 800 | 900 | 720 | Perkins | 4008TAG2A |
| VP1100-5 | 1100 | 880 | 1000 | 800 | Perkins | 4008TAG2A |
| VP1250-5 | 1250 | 1000 | 1125 | 900 | Perkins | 4008-30TAG3 |
| VP1375-5 | 1375 | 1100 | 1250 | 1000 | Perkins | 4012-46TWG2A |
| VP1500-5 | 1500 | 1200 | 1350 | 1080 | Perkins | 4012-46TAG2A |
| VP1650-5 | 1650 | 1320 | 1500 | 1200 | Perkins | 4012-46TAG2A |
| VP1875-5 | 1875 | 1500 | 1650 | 1320 | Perkins | 4012-46TAG3A |
| VP2030-5 | 2030 | 1624 | 1845 | 1476 | Perkins | 4016TAG1A |
| VP2200-5 | 2200 | 1760 | 2000 | 1600 | Perkins | 4016TAG2A |
| VP2500-5 | 2500 | 2000 | 2250 | 1800 | Perkins | 4016-61TRG3 |
| 60HZ | ||||||
| Genset Model | Standby Power | Prime Power | Engine | |||
| kVA | kW | kVA | kW | Brand | Model | |
| VP12-6 | 12 | 10 | 11 | 9 | Perkins | 403D-11G |
| VP17-6 | 17 | 14 | 15 | 12 | Perkins | 403D-15G |
| VP20-6 | 20 | 16 | 18 | 14 | Perkins | 403A-15G2 |
| VP27-6 | 27 | 22 | 24 | 19 | Perkins | 404D-22G |
| VP38-6 | 38 | 30 | 35 | 28 | Perkins | 1103A-33G |
| VP59-6 | 59 | 47 | 53 | 42 | Perkins | 1103A-33TG1 |
| VP75-6 | 75 | 60 | 68 | 54 | Perkins | 1103A-33TG2 |
| VP84-6 | 84 | 67 | 76 | 61 | Perkins | 1104A-44TG1 |
| VP100-6 | 100 | 80 | 91 | 73 | Perkins | 1104A-44TG2 |
| VP125-6 | 125 | 100 | 113 | 90 | Perkins | 1104C-44TAG2 |
| VP169-6 | 169 | 135 | 152 | 122 | Perkins | 1106A-70TG1 |
| VP188-6 | 188 | 150 | 169 | 135 | Perkins | 1106A-70TAG2 |
| VP220-6 | 220 | 176 | 200 | 160 | Perkins | 1106A-70TAG3 |
| VP269-6 | 269 | 215 | 245 | 196 | Perkins | 1506A-E88TAG2 |
| VP313-6 | 313 | 250 | 281 | 225 | Perkins | 1206A-E70TTAG3 |
| VP344-6 | 344 | 275 | 313 | 250 | Perkins | 1506A-E88TAG4 |
| VP438-6A | 438 | 350 | 400 | 320 | Perkins | 2206A-E13TAG5 |
| VP438-6 | 438 | 350 | 400 | 320 | Perkins | 2206C-E13TAG2 |
| VP500-6 | 500 | 400 | 450 | 360 | Perkins | 2206A-E13TAG6 |
| VP563-6 | 563 | 450 | 500 | 400 | Perkins | 2506C-E15TAG1 |
| VP625-6A | 625 | 500 | 563 | 450 | Perkins | 2506C-E15TAG4 |
| VP625-6 | 625 | 500 | 563 | 450 | Perkins | 2506C-E15TAG3 |
| VP688-6 | 688 | 550 | 625 | 500 | Perkins | 2806C-E18TAG1A |
| VP750-6 | 750 | 600 | 688 | 550 | Perkins | 2806A-E18TAG3 |
| VP825-6 | 825 | 660 | 750 | 600 | Perkins | 4006-23TAG2A |
| VP938-6 | 938 | 750 | 844 | 675 | Perkins | 4006-23TAG3A |
| VP975-6 | 975 | 780 | 884 | 707 | Perkins | 4008TAG2 |
| VP1100-6 | 1100 | 880 | 1000 | 800 | Perkins | 4008TAG2 |
| VP1375-6 | 1375 | 1100 | 1250 | 1000 | Perkins | 4012-46TWG2A |
| VP1675-6 | 1675 | 1340 | 1500 | 1200 | Perkins | 4012-46TAG2A |
| VP1880-6 | 1880 | 1504 | 1700 | 1360 | Perkins | 4012-46TAG3A |